n/a

Lamp douses frequently

Lamp Douse

Fan failure...

- check head and enclosure fans for proper operation.

Ballast overheating...

- operating within the specified ambient temperature?
- check enclosure vents for debris / dirt.
- check fan settings in menu.
- check enclosure fans for proper operation.

NOTE: Upon initial power up, ballast fans will run for a few
seconds and then operate as needed. Enclosure vents
must be clear of debris and dirt to allow proper airflow.

n/a

Lamp will not strike

Lamp Strike Failure

Lamp cutout switch disengaged...

- check lamp cutout switches at lamp box and fan ducts.

Bad lamp...

- replace lamp.

Low input voltage...

- check input power (must be 200 to 240 VAC).

Fan failure...

- check head and enclosure fans for proper operation.

n/a

Luminaire behaves oddly

DMX Map Not Matched

Console library not set correctly...

- check console library matches DMX map of luminaire.

n/a

Luminaire does not power
up

No power

Circuit not energized...

- verify circuit breaker (at source) is turned on.

Not plugged in...

- ensure A/C cable is connected to power source.

n/a

Self tests will not run or
software download does
not work from luminaire.

DMX Data Input

Detecting DMX data...

- disconnect DMX input cable.

n/a

No response to DMX data

DMX Failure

DMX connector disconnected...

- check DMX DATA IN connection.

n/a

Erratic control of luminaire

DMX Termination

No DMX termination or termination not correct...

- check for DMX terminator.
- Luminaire DMX address does not match console patch.