c. Once the firmware upload is complete, the VARI

LITE luminaire(s) will automatically

recalibrate.

Step 9. Close PEGASUS Software using

Close

button at bottom of program screen.

Note:

You can confirm the software version in the luminaire menu.

Transferring Software From Luminaire to Luminaire

It is possible to transfer specific software versions between luminaires. As in the case of installing new
software versions, multiple luminaires can be programmed at the same time if they are data linked
together (refer to

“Connecting Data and Power” on page 28

), however a maximum of 32 luminaires

can be updated at once.

Hardware Requirements

Data cables used in this process must have two twisted pairs and a shield. It is also recommended that
cables meet all other USITT DMX specification requirements. Refer to

“Data Cables” on page 17

.

A DMX termination connector is used in this process. Refer to

page 18

for more information regarding

the construction of this connector.

Figure 3-10: Software Transfer Setup

Transfer Procedure

This procedure is used to transfer software versions between luminaires.
Step 1. At last luminaire, install DMX termination connector into DATA THRU XLR connector.
Step 2. At master luminaire (first in chain) Menu Display, press [ESC].
Step 3. Press [Up] / [Down] arrows until

Fixture

appears. Press [OK].

Step 4. Press [Up] / [Down] arrows until

Crossload Software

appears. Press [OK].

Step 5.

OK?

will be displayed. Press [OK] to accept.

Step 6. The status bar will show download progress.

Verify software version at luminaire:

Step 1. At Menu Display, press [ESC].

*DMX terminator required for last fixture on DMX line.

Data In

Termination*

Data Thru

AC In

AC In

AC In

Master luminaire containing

software version to download

Luminaire 1

requiring

Luminaire 2

requiring

Data Thru

update

update

Advertising