Clearance to combustibles, Freestanding models, Fireplace insert – Empire Comfort Systems PV-28SV50-B User Manual

Page 15

Advertising
background image

24820-1-0409

Page 15

CLEARANCE TO COMBUSTIBLES

Freestanding Models

Freestanding Units

A

Rear Wall to Heater

0” (2” Single Flue and 1 1/4” Direct Vent for Serviceability)

B

Side Wall to Heater

0” (4” recommended for serviceability)

C

Corner Installation

0”

D

Mantel Clearance

See Figure 11

Fireplace Insert

Note: The Mantis Power-Vent High-Efficiency Fireplace has been tested and approved for zero clearance to combustible materials.

Empire Comfort Systems, Inc. recommends that clearances as listed above should be maintained to allow for removal of the

product for servicing.

C

C

A

B

B

Figure 7

Figure 8

Single Flue

Requires surround for combustion air.

Do not cover surround louver.

Figure 9

Mantel and Ceiling Clearances

Figure 11

Direct Vent Installation Shown

Single Flue requires surround for combustion air.

Figure 10

12”

18”

24”

8”

6”

4”

COMBUSTIBLE TRIM AND MANTELS

ALLOWED IN SHADED AREA

40”

CEILING

Advertising