Pvvk-24h and pvvk-48h vent kit – Empire Comfort Systems PV-28SV50-B User Manual

Page 32

Advertising
background image

24820-1-0409

Page 32

Available from Empire Comfort Systems, Inc.

Step 1. Install foam gasket on back side of co-axial direct

vent adaptor.

Step 2. Attach co-axial direct vent adaptor and gasket (4

screws) to the rear of fireplace.

Step 3. Attach co-axial air-inlet duct to rear of fireplace (6

screws).

Step 4. Install silicone around connection between co-ax-

ial adaptor and co-axial air-inlet duct.

4 1/2”

MINIMUM VENT LENGTH

3 13/16”

MINIMUM TUBE LENGTH

Step 5. Slide co-axial vent pipes into co-axial adaptor.

Cut the PVC co-axial pipes at this time.

Minimum horizontal vent length 4 1/2” (11.4 cm)

Minimum tube length 3 13/16” (9.7 cm)

Step 6. Direct vent co-axial venting is completed.

PVVK-24H AND PVVK-48H VENT KIT