PVCT COLINEAR TRANSITION VENT KIT

Available from Empire Comfort Systems, Inc.

Flat Roof or Chimney Application

1. Attach plate to chimney chase or flat roof with four (4) screws. Use outdoor sealant to seal transition plate to the roof or chimney

chase.

2. Check local codes to determine air intake height from roof. The minimum height for this application is 12”.

3. Cut 1 1/2” PVC pipe to correct height. Attach pipe, PTrap, and exhaust cap to plate. Glue all joints with PVC cement.

AIR INTAKE

PTRAP OR 2 90° ELBOWS

SUPPLIED BY INSTALLER

TRANSITION PLATE

PVC CEMENT

PVC CEMENT

OUTDOOR SEALER REQUIRED

OPTIONAL

CAP

MODEL PVVTC

ORDER SEPARATE

EXHAUST

3” MIN.

HEIGHT (MIN. 12”)

Horizontal Application

1. Attach plate to outside wall with four (4) screws. Use outdoor sealant to seal transition plate to the wall.

2. Cut 1 1/2” PVC pipe to correct length. The minimum length for this application is 9” for the exhaust and 6” for the air intake. Glue

all joints with PVC cement.

Colinear Transition Plate

AIR INTAKE

PTRAP OR 2 90° ELBOWS

SUPPLIED BY INSTALLER

TRANSITION PLATE

PVC CEMENT

PVC CEMENT

OUTDOOR SEALER REQUIRED

3” MIN.

HEIGHT (MIN. 12”)

EXHAUST

PTRAP OR 2 90° ELBOWS

SUPPLIED BY INSTALLER

Note: Must maintain a minimum 3” between

exhaust outlet and air intake.

Note: Exhaust must be a minimum of 3” above air intake inlet.