Pvvk-cfa flex vent kit – Empire Comfort Systems PV-28SV50-B User Manual

Page 22

Advertising
background image

24820-1-0409

Page 22

Available from Empire Comfort Systems, Inc.

PVVK-CFA FLEX VENT KIT

The flex vent kit is a flexible vent hose that is 42” in length. The flex vent kit will be used when installing a Mantis into an existing

fireplace. The flex vent kit can be cut down, but can only be cut from one end.

Cement PVC Joints

Cut End

Cement PVC Joints

Once length is determined, install two (2) 10 x 1/2” screws into the adaptor assembly to secure the adaptor assembly to the flex hose.

Using PVC cement, cement all PVC joints of the flex vent kit to the remaining PVC vent run.

FLEXIBLE

FLUE KIT

FLEXIBLE GAS

LINE

PVC PIPE SWV

(SUPPLIED BY INSTALLER)

(2) - 45 DEG. PVC BENDS

(SUPPLIED BY INSTALLER

IF NECCESSARY)

GALV. SHEET FLASHING

TO SEAL CHIMNEY

(SUPPLIED BY INSTALLER)

VENT CAP (SUPPLIED

WITH VENT KIT)

CUT END

Venting for Existing Fireplace Installation

Determining Minimum Vent Height Above the Roof
WARNING:
Major U.S. building codes specify minimum chimney and/or vent height above the rooftop. These minimum heights are

necessary in the interest of safety.

ROOF PITCH

H (Min.)

Flat to 6/12

12” (305 mm)

6/12 to 7/12

15” (381 mm)

Over 7/12 to 8/12

18” (457 mm)

Over 8/12 to 16/12

24” (610 mm)

Over 16/12 to 21/12 36” (914 mm)