Empire Comfort Systems PV-28SV50-B User Manual

Page 9

Advertising
background image

24820-1-0409

Page 9

1. Pick a location on a wall with a clear space in the room. In

selecting a location for installation, it is necessary to provide

adequate accessibility clearances for servicing and proper

installation. Be sure to locate the unit close enough to a 110

VAC wall receptacle to properly power appliance.

2. When facing the front of the furnace the minimum clearances

from casing to combustible construction are 0” (0 mm) on top,

0” (0 mm) on each side, recommend 4” (102 mm) on sides

for servicing and 0” (0 mm) from the floor, 0” (0 mm) to rear

wall and 40” (1,016 mm) from Mantis top to ceiling.

3. The minimum distance from the center of the vent cap to the

nearest outside corner or obstruction is 12” (305 mm).

4. The minimum wall depth is 4” (102 mm) and the maximum

is 48” (121.92 cm).

The vent terminal of a direct vent appliance, with an input of

50,000 BTU (14.6KW) per hour or less shall be located at least

9” (229 mm) from any opening through which flue gases could

enter a building.

The bottom of the exhaust vent terminal and the air intake shall

be located at least 12” (305 mm) above grade and must be vented

outside.

WARNING: The nearest point of the vent cap should be

a minimum horizontal distant of six (6) feet (1.83 m) from

any pressure regulator. In case of regulator malfunction,

the six (6) feet (1.83 m) distance will reduce the chance of

gas entering the vent cap.

Installation on Rugs and Tile

If this appliance is to be installed directly on carpeting, tile, or other

combustible material, other than wood flooring, the appliance shall

be installed on a metal or wood panel extending the full width and

depth of the appliance.
The base referred to above does not mean the fire-proof base as

used on wood stoves. The protection is primarily for rugs that may

be extremely thick and light-color tile that can discolor.

Locating Wall Opening

The recommended location for this furnace is on an outside wall.

Locate wall studs so that wall vent opening will be located between

wall studs. The wall opening required for venting is a 3 1/2” (89

mm) minimum diameter opening.
Refer to Figures 3 and 6 for positioning the heater on wall and for

locating gas line connection and vent opening. Furnace can sit on

the floor.

CLEARANCES FOR DIRECT VENT

HEATER INSTALLATION FOR DIRECT VENT

1 9/16”

4 3/32”

Figure 2