Log set installation instructions – Empire Comfort Systems PV-28SV50-B User Manual

Page 18

Advertising
background image

24820-1-0409

Page 18

All Logs

The positioning of the logs is critical to the safe and clean opera-

tion of this heater. Sooting and other problems may result if the

logs are not properly and firmly positioned in the appliance.
6. Prior to positioning of top left log and top right log, inspect

front burner and rear burner for particles or dust accumula-

tion on top of burners. If any particles or dust is visible on top

of front or rear burners, remove particles before placing top

left log and top right log into position.

7. Position top left log into locating pin on rear log and rest on

center log. See Figure 15.

8. Position top right log into locating slot on rear log. See Fig-

ure 15.

9. After top left log and top right log have been placed in posi-

tion and safety check has been carried out, install door and

latch securely with latches located on right and left side of

heater.

LOG SET INSTALLATION INSTRUCTIONS

Log Installation

The gas log set (front left log, front right log, center log and rear

log) is pre-set and installed in the factory. Only the top left log and

top right log are packaged separately inside the firebox for instal-

lation by the installer.
1. To access the log set parcel, lift off top panel.
2. Pivot left and right panels open.
3. Unlatch main door latches located on right and left hand side

of the heater, remove door.

4. Carefully remove top left log and top right log from firebox

and remove cardboard protection from center log and middle

log and all packaging materials.
Note: Positions of front left log, front right log, center log,

and rear log have been preset at the factory and their loca-

tions should not be changed. Check that logs have not been

damaged in transit.

5. Carefully remove wrapping from top left log and top right

log.

Note: Before you begin: Do not handle these logs with your bare

hands! Always wear gloves to prevent skin irritation. After

handling logs, wash your hands gently with soap and wa-

ter.

FRONT RIGHT LOG

FRONT LEFT LOG

CENTER LOG

TOP LEFT LOG

REAR LOG

TOP RIGHT LOG

LOG SET DIAGRAM - A

The Gas Log Kit contains the following:

1)

Rear Log

2)

Center Log

3)

Top Right Log

4)

Top Left Log

5)

Front Left Log

6)

Front Right Log

1 - REAR LOG

3 - TOP RIGHT LOG

6 - FRONT RIGHT LOG

2 - CENTER LOG

5 - FRONT LEFT LOG

4 - TOP LEFT LOG

Figure 15