Vertical examples for colinear direct vent – Empire Comfort Systems PV-28SV50-B User Manual

Page 26

Advertising
background image

24820-1-0409

Page 26

VERTICAL EXAMPLES FOR COLINEAR DIRECT VENT

SINGLE FLUE

MODEL PVVK-SH

CO-LINEAR

DIRECT VENT ADAPTER

MODEL PVCA

12

X

HEIGHT

FLASHING

REQUIRED

HEIGHT

AIR INTAKE

PTRAP, 2 90° ELBOWS (SUPPLIED

BY INSTALLER) OR TERMINATION CAP

MODEL PVVTC. PTRAP TO FACE

AWAY FROM ROOF.

EXHAUST

TERMINATION CAP

MODEL PVVTC, PTRAP

OR 2 90° ELBOWS

OPTION

3” - 24”

Colinear Direct Vent - Insert Installation

Figure 29

Colinear Direct Vent - Pitched Roof Installation

Figure 30

Determining Minimum Vent Height Above the Roof
WARNING:
Major U.S. building codes specify minimum chimney and/or vent height above the rooftop. These minimum heights are

necessary in the interest of safety. These specifications are summarized in Figure 30.

ROOF PITCH

H (Min.)

Flat to 6/12

12” (305 mm)

6/12 to 7/12

15” (381 mm)

Over 7/12 to 8/12

18” (457 mm)

Over 8/12 to 16/12

24” (610 mm)

Over 16/12 to 21/12

36” (914 mm)

Figure 31

In both vertical and horizontal colinear direct vent applications, a colinear

transition plate model PVCT can be used to minimize clearances between

intake and exhaust pipes.
For exhaust and intake air, cap pipes with any of the following: Vertical

termination cap (model #PVVTC), PTrap, or two 90º elbows. When transi-

tion plate (model PVCT) is used, two termination caps (model PVVTC) may

NOT be used.

Note: If transition plate (model PVCT) is used, the measurement for center

to center of the pipes will be 2.5”. If the transition plate (model PVCT) is

not used, the measurement for center to center of the pipes can be 3” to 24”

maximum.

Note: Exhaust must be a minimum

of 3” above air intake inlet.

Advertising
This manual is related to the following products: