DIRECT VENT INSTALLATION INSTRUCTIONS (cont.)

EXTERIOR GRADE

FLUE CENTER

1 1/4”

(3.2cm)

MIN.

12”

(30.5cm)

MIN.

FLOOR PROTECTION

FLOOR PROTECTION

NO HEARTH REQUIRED

EXTERIOR GRADE

FLUE CENTER

1 1/4”

(3.2cm)

MIN.

12”

(30.5cm)

MIN.

Figure 36

Minimum Exterior Grade Dimension - Unit Without Pedestal

Figure 37

Minimum Exterior Grade Dimension - Unit With Pedestal

Installation on Rugs and Tile

If this appliance is to be installed directly on

carpeting, tile, or other combustible mate-

rial, other than wood flooring, the appliance

shall be installed on a metal or wood panel

extending the full width and depth of the

appliance.
The base referred to above does not mean

the fire-proof base as used on wood stoves.

The protection is primarily for rugs that may

be extremely thick and light-color tile that

can discolor.

EXTERIOR GRADE

FLUE CENTER

12”

(30.5cm)

MIN.

Figure 38

Minimum Exterior Grade Dimension - Existing Fireplace Installation