Keystone Correction Parameters

When you output an image from a
projector at an angle, the image may
appear skewed. Eight Keystone
parameters

Top

Top Left X

Top Right X

Top

Bottom

Right Y

Bottom Right X

Bottom Left X

Bottom

Left Y

Right Y

Left Y

Original Content

adjust the image shape

and compensate for this effect. You
can control each of the four corners
of the graphics output to reshape
your image to a form that projects
correctly.

Default DMX Value: 0 = no
keystone correction has been
applied. Each corner has an x and a y
value that adjust and correct scale of
the projection from any corner toward the image center on that axis.

Keystone Top Left X DMX value = 85
Keystone Top Left Y DMX value = 85
Keystone Top Right X DMX value = 85
Keystone Top Right Y DMX value = 85

Keystone Top Right Y DMX value = 170
All other Keystone parameter DMX values = 255

Setting all Keystone X and Y parameters DMX values to zero will place the four corners of the
image at the four corners of the projector output. Adjusting keystone x values toward 255
(100%) moves the respective corner x positions horizontally toward the center of that image
edge. Adjusting keystone y values toward 255 (100%) causes the respective corner y positions
to be moved vertically toward the center of that edge of the image.

Tip: These parameters can also be used to create interesting skewing as a design effect.

Note: DL.3 fixtures have vertical lens shift capability that provides additional

keystone control. Engage lens shift with your DMX console in the Control

Parameter of the Motion Control fixture type.