Configuring axon – High End Systems AXON User Manual

Page 33

Advertising
background image

CHAPTER 2

Setup and Configuration

Axon Media Server User Manual

13

Configuring Axon

Before programming the Axon media server from a DMX512 console, you need to:

• Identify the DMX Source for the fixture

• Select the Protocol type to determine the DMX channel range this fixture will utilize

• If you will be synchronizing output between fixtures, verify that each server has a unique

Fixture Number to identify it on the Ethernet link.

• Assign a valid Start Channel (the first channel in the unique range of DMX channels

designated by the console for this Axon)

To view configuration information for a individual server, click on All Servers in the left pane of
the CMA window and select the + to view all the servers on the fixture network. Select a server in
the left pane to view its configuration information in the right pane.