Zone Response Type Definitions

Type 07
24-hour

Audible

Alarm


Zone type 07 is usually assigned to a zone containing an Emergency
button (audible emergency).
Zone Characteristics:
• Sends a report to the central station, and provides alarm sounds

externally and at the keypad.

Type 08
24-hour

Auxiliary Alarm

Zone type 08 is usually assigned to a zone containing a button for use
in personal emergencies or to a zone containing monitoring devices
(i.e.: water or temperature sensors, etc.).
Zone Characteristics:
• Sends a report to the central station and provides an alarm sound at

the keypad. (No bell output is provided and there is no keypad
timeout.)

5806/5807/5808

01000-020-V0

Type 09

Supervised

Fire

Zone type 09 can be assigned to any wireless zone used as a
fire zone. This zone type is always active and cannot be
bypassed.
Zone Characteristics:
• Bell output will pulse when this zone type is alarmed.

Type 10

Interior w/Delay

Zone type 10 is bypassed when the panel is armed in the STAY or STAY
NO DELAY mode.
Zone Characteristics:
• Entry delay #1 (with programmed entry time) when armed in the

AWAY mode.

• Entry delay begins whenever sensors in this zone are violated,

regardless of whether an entry/exit delay zone was tripped first.

• No entry delay when armed in the AWAY NO DELAY mode.

• Exit delay regardless of the arming mode selected.

Type 20

Arm–Stay

Zone type 20 is a special-purpose zone type used with 5800 Series
wireless pushbutton units.
Zone Characteristics:
• Exit delay regardless of the arming mode selected.

• System is armed in the STAY mode when the zone is activated.

• Zone number is sent to the central station as a user number when

arming or disarming.

Type 21

Arm–Away

Zone type 21 is a special-purpose zone type used with 5800 Series
wireless pushbutton units.
Zone Characteristics:
• System is armed in the AWAY mode when the zone is activated.

• Zone number is sent to the central station as a user number when

arming or disarming.

Type 22

Disarm

Zone type 22 is a special-purpose zone type used with 5800 series
wireless pushbutton.
Zone Characteristics:
• Disarms the system when the zone is activated.

Type 23

No Alarm Response

Zone type 23 can be used on a zone when a Powerline Carrier Device
(e.g., X-10) action is desired, but with no accompanying alarm (e.g.,
front door light).

Type 24

Silent Burglary

Zone type 24 is usually assigned sensors or contacts on exterior doors
and windows where bells and/or sirens are NOT desired.
Zone Characteristics:
• Instant alarm, with NO audible indication when is armed in the

AWAY, STAY, STAY NO DELAY, or AWAY NO DELAY mode.

• Report sent to the central station.

Note: Keypad beeps if the zone is faulted when system is disarmed and Chime

mode is on.