LYNXR/LYNXR24 PROGRAMMING DEFAULT TABLES

(boldface indicates defaults that differ between tables)

Function

Table 1

Table 2

Table 3

Table 4

*20 Installer code

4112

4112

4112

4112

*21 Quick arm enable

1

1

1

1

*22 Keypad backlight timeout

0

0

0

0

*23 Forced bypass

0

0

0

0

*24 RF house ID code

0,0

0,0

0,0

0,0

*25 Powerline carrier device house code

0

0

0

0

*26 Chime-by-zone

0

0

0

0

*27 Real-time clock display

1

1

1

1

*29 Daylight saving time start/end month

4,10

4,10

4,10

4,10

*30 Daylight saving time start/end weekend

1,5

1,5

1,5

1,5

*31 Single alarm sounding per zone

0

0

0

0

*32 Fire sounder timeout

0

0

0

0

*33 Alarm bell timeout

1

1

1

1

*34 Exit delay

7,0

6,0

7,0

7,0

*35 Entry delay 1 (zone type 01)

3,0

4,5

3,0

3,0

*36 Entry delay 2 (zone type 02)

6,0

6,0

6,0

6,0

*37 Audible exit warning/quick exit

1,1

0,1

1,1

1,1

*38 Confirmation of arming ding

0

0

0

0

*39 Power up in previous state

1

1

1

1

*40 PABX access code

---

---

---

---

*41 Primary phone number

---

---

---

---

*42 Secondary phone number

---

---

---

---

*43 Primary subscriber account number

15,15,15,15

15,15,15,15

15,15,15,15

15,15,15,15

*44 Secondary subscriber account number

---

---

---

---

*46

“Follow Me Reminder” Phone Number

---

---

---

---

*47 Phone system select

1

1

1

1

*48 Report format

7,7

7,7

7,7

7,7

*49 Split/dual reporting

0

0

0

9

*50 15 second dialer delay (burglary)

0

1

0

0

*51 Periodic test report

0

3

0

0

*52 First test report offset

2

2

2

2

*53 Sescoa/radionics select

0

0

0

0

*54 Lack of usage notification

0

0

0

0

*55

Wireless Dialer

0, 0, 0, 0

0, 0, 0, 0

0, 0, 0, 0

0, 0, 0, 0

*56 Enhanced Zone programming

See *56 table

See *56 table

See *56 table

See *56 table

*58 RF jam detection

0

0

0

0

*59 Exit error report code

1

0

1

1

*60 Trouble report code

1,0

1,0

1,0

1,0

*61 Bypass report code

0,0

0,0

0,0

0,0

*62 AC loss report code

0,0

0,0

0,0

0,0

*63 Low battery Report code

1,0

1,0

1,0

1,0

*64 Test report code

1,0

1,0

1,0

1,0

*65 Open report code

0

0

0

0

*66 Arm away/stay report code

0,0

0,0

0,0

0,0

*67 RF transmitter low battery report code

1,0

1,0

1,0

1,0

*68 Cancel report code

1,0

1,0

1,0

1,0

*70 Alarm restore codes

1

1

1

1

*71 Trouble restore report code

1,0

1,0

1,0

1,0

*72 Bypass restore report code

0,0

0,0

0,0

0,0

*73 AC restore report code

0,0

0,0

0,0

0,0

*74 Low battery restore report code

1,0

1,0

1,0

1,0

*75 RF transmitter low battery restore report code

1,0

1,0

1,0

1,0

*76 Test restore report code

0,0

1,0

0,0

0,0

*80 Powerline Carrier Devices

See *80 table

See *80 table

See *80 table

See *80 table

*81 Zone lists for devices

See *81 table

See *81 table

See *81 table

See *81 table

*84 Assign zone voice descriptors

Refer to *84 Programming

*87 Auxiliary Function/ 1-button paging

0

1

0

1

*88 Pager characters

---

---

---

---

*89 Event log 80% full report code

0,0

0,0

0,0

0,0

*90 Event logging

3

15

3

3

*91 LRR/AAV Trigger/Remote Phone Control

2

2

2

2

*92 Number of reports in armed period

0

0

0

0

*93 Flexible call back

0

0

0

0

*94 Download phone number

---

---

---

---

*95 Ring detect count for downloading/remote phone control

15

15

15

15

Default Master Code

1,2,3,4

1,2,3,4

1,2,3,4

1,2,3,4

Default

Duress

Code

--- --- --- ---

By activating *96, Field 43, and 44 will be changed to 15, 15, 15, 15.