83 enhanced sequential mode – Honeywell ADEMCO LYNXR-EN User Manual

Page 37

Advertising
background image

–37–

83 Enhanced Sequential Mode

Ib

zz


Ib

Serial number

Enter transmitter’s 7- digit serial number via RF

learning or manually.

[#] = return to (1A) prompt and reject whatever

serial number entries have been made.

[✻] = return to (1A) prompt (if a valid serial

number has been enrolled, “L” is displayed

and the serial number will be copied into

EEROM and the last serial entered buffer.

Note: For zones 26, 30, 34 and 38 only BR type

devices can be used.

This prompt can be used to enroll the transmitter serial number via

RF transmission or manually. If using the RF Learning Mode there
is no need to manually enter a serial number. Proceed directly to RF
Learning. Upon entering the Serial Number mode, the Zone
Descriptors will be announced.

Note: BR type devices can be enrolled only by transmission from BR

devices. Likewise, UR and RF devices can only be enrolled by
transmission from a UR or RF device

RF Learning - Two (2) transmissions (2 key depressions) at least
five seconds apart, will be required for BR type or four (4)
transmissions (fault, restore and fault, restore) for UR or RF type. If
the learned serial number has a different loop number than that
entered in

56 the system will announce the Voice Descriptor, if it

is programmed, followed by two beeps and will return to Prompt (1A)
and “L” will be displayed.

If the loop number captured by RF transmission and that entered in

56 mode match, the system will announce the Voice Descriptor, if it

is programmed, followed by three beeps and return to Prompt (1A)
and “LC” will be displayed. No additional transmissions are needed
for confirmation.

Manual Entry - Enter the 7-digit serial number printed on the

transmitter. If you enter an incorrect digit, press the [#] key to
backup to prompt (1A) and start over. When all 7 digits are entered,
press the [

] key. If less than 7 digits are entered, the keypad will

emit a single long beep and return to the (1A) prompt without
displaying the “L”.
If more than 7 digits have been entered, the first 6 digits will be
saved along with the last digit that was entered (entering 123456789
yields the serial number 1234569).

Note: If 52 seconds pass and no entry has been made, the system

returns to prompt (1A).

F

Delete serial number

0 = discard the delete request

1 = confirm requested delete

Note: Entering a “9” at prompt (1A) will cause the

panel to return to prompt (1A) regardless of
the confirmation answer.

This function deletes only the serial number.

Entering a “9” at prompt (1A). Confirmation of the delete request will
cause deletion of the serial number pertaining to the zone being
programmed.

Note: In Enhanced Sequential Learn Mode, 4 button type keys will always be learned simultaneously. They will be stopped at the 4

button boundaries of 26, 30, 34 and 38, provided the zone is free of a serial number. If the first zone of the key has a serial
number learned, the remaining keys cannot be programmed in sequential learn mode. In addition, if the zone has not been set
up (duplicate loop, missing zone type, etc.) only entries 0 (skip to the next zone) and 4 (copy the key template) will be allowed.