System Communication

Report

3+1/4+1 Standard

3+1/4+1 Expanded

4+2

Alarm

SSS(S) A

SSS(S) A
AAA(A) Z

SSSS AZ

Trouble

SSS(S) T

SSS(S) T
TTT(T) t

SSSS Tt

Bypass

SSS(S) B

SSS(S) B
BBB(B) b

SSSS Bb

AC Loss

SSS(S) E

SSS(S) E
EEE(E) AC

SSSS EAC

Low Battery

SSS(S) L

SSS(S) L
LLL(L) LB

SSSS LLB

Open

SSS(S) O

SSS(S) O
OOO(O) U

SSSS OU

Close

SSS(S) C

SSS(S) C
CCC(R) U

SSSS CU

Test

SSS(S) G

SSS(S) G
GGG(G)g

SSSS Gg

Restore Alarm

SSS(S) R

SSS(S) R
RRR(R) Z

SSSS RZ

AC Restore

SSS(S) RA SSS(S)

RA

RARARA(RA)Ac

SSSSRA Ac

Low Battery Restore

SSS(S) RL SSS(S)

RL

RLRLRL(RL)LB

SSSS RLLB

Trouble Restore

SSS(S) RT SSS(S)

RT

RTRTRT (RT)t

SSSS RTt

Bypass Restore

SSS(S) RB

SSS(S) RB
RBRBRB (RB)b

SSSS RBb

ADEMCO Contact ID® Reporting takes the following format: CCCC Q EEE GG ZZZ where:
CCCC = Customer (subscriber) ID
Q =

Event qualifier, where: E = new event, and R = restore

EEE = Event code (3 hex digits) (for a complete list of event codes, refer to the central office receiver manual)
GG =

Always “00”

ZZZ =

Zone/Contact ID® number reporting the alarm, or user number for open/close reports. System
status messages (AC Loss, Walk Test, etc.) contain zeroes in the ZZZ location.

CONTACT ID® EVENT CODES

Code

Definition

110 Fire

Alarm

121 Duress
122

Alarm, 24-hour Silent

123

Alarm, 24-hour Audible

131 Alarm,

Perimeter

132 Alarm,

Interior

134 Alarm,

Entry/Exit

135 Alarm,

Day/Night

145

Wireless Dialer Tamper

(plus Zone 93) (Alarm)

146 Silent

Burglary

150

Alarm, 24-Hour Auxiliary

301 AC

Power

338

Wireless Dialer Low Battery

(plus Zone 93)

341

Wireless Dialer Tamper

(plus Zone 93)

(Trouble)

342*

Wireless Dialer AC Loss

(plus Zone 93)

344

RF Jam Detected

351*

Wireless Dialer Phone Line Cut

(plus Zone 93)

354

Fail to Report

355

Wireless Dialer Loss of RF Supervision

(plus Zone 93)

355

(Zone 000) Reported by the 5842 Wireless Dialer

373

Fire Loop Trouble

374

Exit Error Alarm

*If supported by the 5842 Wireless Dialer that is installed.

Code

Definition

380

Global Trouble, Trouble Day/Night

381

RF Supervision Trouble

383

RF Sensor Tamper

(Trouble)

384

RF Sensor Low Battery

401

Disarmed, Armed AWAY (NO DELAY),

Armed AWAY

403

Scheduled Auto Arm

406 Cancel

by

User

407

Remote Arm/Disarm (Downloading)

408

Quick Arm AWAY/NO DELAY

441

Disarmed/Armed STAY/NO DELAY, Quick Arm

STAY/NO DELAY

570 Bypass
602 Periodic

Test

606

AAV to follow

607 System

Test

623

Event Log 80% Full

654 System

Inactivity

NOTE: The following codes are logged in the event log upon

occurrence, but are not reported:

305 = System Reset

627 = Keypad Program Mode Entry