System operation – Honeywell ADEMCO LYNXR-EN User Manual

Page 47

Advertising
background image

–47–

System Operation

Security Codes

Installer Code

The installer programs the 4-digit Installer Code initially as part of the programming procedure. The
factory default Installer Code is 4-1-1-2, but may be changed in field

20.

The Installer Code is the only code that can enter Programming mode and also, in normal operation
mode, is used to enter the Master Code, which allows access to the normal functions of the system.

Master Code
In normal operation mode, the Installer Code is used to enter the 4-digit Master Security Code.
To enter/change the Master code by installer, using the keypad enter:

Installer Code + [CODE key] + [02] + desired 4-digit Master Code

To change the Master code by master, using the keypad enter:

Current Master Code + [CODE key] + [02] + new Master Code + new Master Code again

Secondary User Codes
In normal operation mode, the Master Security Code can be used to assign up to 6 secondary 4-digit security
codes, including a Babysitter Code and a Duress Code. The Master Code can also be used to remove
secondary codes from the system (individually).

To assign (or change) a secondary security code, using the keypad enter:

Master Code + [CODE key] + User # (03–08) + desired Secondary Code

The system will emit a single beep when each secondary code has been successfully entered.

To delete a secondary security code, using the keypad enter:

Master Code + [CODE key] + User # (03–08)

Security Code Notes

The Master and Secondary security codes permit access to the system for arming, disarming, etc.

• The Installer Code can disarm the system only if it was used to arm it. In addition, the Installer Code cannot disarm

the system if it was armed by pressing and holding a Quick-Arm button.

• The Babysitter Code (User Code No. 7) can disarm the system only if it was used to arm it. In addition, the

Babysitter Code cannot disarm the system if it was armed by pressing and holding a Quick-Arm button.

• Duress code (User Code No. 8) sends a special code to the monitoring station when used to perform any system

operation.. Instruct users to be careful not to use this code for normal usage.

• If a secondary code is inadvertently repeated for different users, the lower user number will take priority.
• Opening/closing reports are sent for the Installer Code as No. 01, with the appropriate subscriber number. Master

Code and set of secondary user codes are sent as Nos. 02 and 03–08, respectively, in Contact ID® format (with the
appropriate user number); in 4+2, it is 1–8. Quick arming (and open/close executed by downloader) is reported as
user 00.

Panic Keys

There are three panic key pairs that, if programmed, can be used to manually initiate alarms and send a
report to the central station.
Each can be individually programmed for 24-hour silent, audible, personal or fire emergency responses. The
panic function is activated when both keys of the appropriate key pair are pressed at the same time.
The panic functions are identified by the system as follows:

Keys

Displayed as Zone

[1] & [

] 95

[

] & [#]

99

[3] & [#]

96


Important:
For the silent panic functions
to be of practical value, the system must be
connected to a central station.