Wiring Connections

Wiring Overview

The following summarizes the connections required. Refer to the Wiring Connections paragraph and the Summary of
Connections diagram on the inside back cover when making connections.












MXXXX K5108

01009-005-V0












Wiring Connections

1. Make Earth Ground Connection

-

The designated earth ground terminal (1) must be terminated in a good earth ground

for the lightning transient protective devices in this product to be effective. The following are examples of good earth
grounds available at most installations:
Metal Cold Water Pipe - Secure a non-corrosive metal strap (copper is recommended) to the pipe that is electrically
connected and secured to which the ground lead.
AC Power Outlet Ground - Available from 3-prong, 120VAC power outlets only. To test the integrity of the ground
terminal, use a three-wire circuit tester with neon lamp indicators, such as the UL Listed Ideal Model 61–035, or
equivalent, available at most electrical supply stores.

a. Connect terminal 1 to a good earth ground.

EARTH GROUND

See Earth Ground paragraph.

PHONE LINES

Use either the plug-in jacks or
the screw terminals.

HARDWIRE ZONE

Supports 1 EOLR supervised zone using either closed
circuit or open circuit sensors.

SOUNDERS

The system includes a built-in sounder in the master keypad. If

desired, an external bell or piezo sounder can be connected.

Bell: Use a 6-14V bell with maximum current drain of 120mA.

Piezo: Use a 6-14V piezo sounder with maximum current drain of

30mA.

This control complies with NFPA requirements for temporal pulse

sounding of fire notification appliances.

Temporal pulse sounding for a fire alarm consists of the following:
3 pulses – pause – 3 pulses – pause – 3 pulses. . .

POWERLINE CARRIER DEVICES

Supports up to 8 Powerline Carrier

Devices for turning on/off lights and

appliances. Requires the use of an
ADEMCO 1332X10 transformer.

AC TRANSFORMER

Use the supplied

ADEMCO 1332X10

9VAC, 15VA Plug-in

Transformer (1332CN in

Canada).

LOCAL SOUNDER DISABLE JUMPER

Remove the shorting jumper (shunt) to disable local

sounder, leaving only the external sounder active.

UL NOTE: Do not remove the shorting jumper (the shunt)

for UL installations.

LONG RANGE RADIO

Compatible with the ALARMNET 7845C and 7720
Devices.

TWO-WAY VOICE

The LYNXR-EN supports the two-way

voice feature/Alarm Audio Verification.

The LYNXR and LYNXR24 require the

installation of the LYNXAVM.