background image

Terminal Interfaces

2-3

RS-232 Interface Installation

Verify the RS-232 port (COM1 or COM2) available on your
computer system.

Plug the RJ45 phone plug of the main cable into the RS-232
cable adapter.

Plug the 9-pin or 25-pin D-sub connector of the cable converter
into the desired serial port on your system.

A

ttach the power outlet plug of the optional AC power adapter to

the side power jack of the D-sub connector.

You will hear the

power-on beep twice to signal that the scanner is ready for bar
code reading. Scan the “

RS-232 Serial Interface bar code to

configure the scanner to perform the RS-232 serial interface
operation.

RS-232 Serial Interface

Scanning the RS-232 interface bar code above configures the
scanner’s serial parameters to 9600 Baud, 8 data bits, no parity,
and 1 stop bit, no handshaking.
Please note that the RS-232 settings of the host system must
match the scanner’s RS-232 settings.

If you are in the Windows

®

environment, you may use the “

Hyper

Terminal” to test.

Standard RS-232 Pinouts

PIN-1: VCC (5V)
PIN-2: TD
PIN-3: RD
PIN-4: NC
PIN-5: GND
PIN-6: NC
PIN-7: CTS
PIN-8: RTS
PIN-9: VCC (5V)

(

+

)

(

-

)

9 Pin D-sub RS-232 Female Connector

(

+

)

(

-

)

PIN-2: RD

PIN-3: TD
PIN-4: CTS
PIN-5: RTS
PIN-6: NC
PIN-7: GND
PIN-16: VCC (5V)
PIN-25: VCC (5V)

25 Pin D-sub RS-232 Female Connector