Hand Held Products 3080 User Manual

Page 52

Advertising
background image

Programming the Scanner

3-38

[Data Verifier]

Scan “Program” to enter the programming mode.

Scan “Verifier Control” and set bar code symbology to
08” (Interleaved 2 of 5).

Scan “Identified Data Length” and set the length to “16.”

Scan “1st Identified Character” and set the identified position to
00,” then set the identified character to “39” (Hex value for 9).

[Data Formatter]

Scan “Formatter Control” and set bar code symbology to “08.”

Scan “1st Insertion” and set the identified position to “06,” then
inserted characters to “09” (Hex value for TAB), “53” (Hex value
for S), “4E” (Hex value for N).

Scan “2nd Insertion” and set the identified position to “12,” then
inserted character to “09.” Finally, you must scan the “FIN
(Finish) code to terminate this selection.

Scan “3rd Insertion” and set the identified position to “16,” then
inserted character to “09.” Finally, you must scan the “FIN
(Finish) code to terminate this selection.

[Data Replacer]

Scan “Replacer Control” and set bar code symbology to “08.”

Scan “1st Replacement” and set the identified position to “00,”
then replaced character to “41” (Hex value for A).

At this point the data string is as follows:

A81025[TAB]SN123456[TAB]9876[TAB]. We still need to delete
the 98 from the string to get the desired output.

[Data Organizer]

Scan “Organizer Control” and set bar code symbology to “08.”

Scan “1st Organization” and set the identified position to “16,”
then set the data transmission to “0” (before).

The character position, which counts the added “SN” and TABs,
is identified as 00, 01, 02,… so the 16

th

character is “9.” The

include/exclude control, which will be set to 0 for exclude in the
last step of the instructions below, determines that the “9” in the
16

th

position will not be sent. All of the characters before the 16

th

position will be transmitted.

Scan “2nd Organization” and set the identified position to “17,”
which is “8,” in this case, then set the data transmission to “1
to transmit all of the characters after position 17. Whether
position 17 gets transmitted along with the string is determined
by the include/exclude control, which, in this case, will be
excluded in the next step.

[Include/Exclude Control]

Scan “Include/Exclude Control”.

Scan “0” for transmitted data excluding the data of the identified
position.

Scan “END” (Exit) to terminate the programming.

Advertising