Beeping indications – Hand Held Products 3080 User Manual

Page 61

Advertising
background image

Appendix

A-4

Beeping Indications

No.

Descriptions

Beeping

Buzzer Tone

01 Internal or operation memory error

Repeated beeps

medium

02 Internal fatal error

Repeated beeps

medium

03 Beginning the normal operation

2 short beeps

high + low

04 Entering the programming mode (Program)

3 short beeps

high + low + low

05 Exiting the programming mode (End)

1 short beep

medium

06 Completing to store the parameters

3 short beeps

low + medium high

07 Starting the master default and group default

4 short beeps

high medium + high + medium

08 Completing the master default and group default

3 short beeps

low + high + low

09 Completing the system information listing

3 short beeps

medium + high + medium

10 Good reading

1 short beep

adjustable tone

11 Programming error (Invalid programming scan)

1 long beep

medium

12 Scanning “FIN” to finish programming selection

2 short beeps

medium + medium

13 Finishing the programming selection automatically 2 short beeps

medium + medium

14 Data verifier checking error

3 long beeps

medium + medium + medium

15 Memory buffer full

4 long beeps

medium + medium + medium + medium

16 Time out warning

2 long beeps

medium + medium

17 No CTS signal warning

1 long beep

medium

18 Record over-size warning

1 long beep

low