Relink Time-Out

Relink Time-Out controls the idle time between re-link attempts. An attempt to
link an image scanner to a base unit typically lasts up to 5 seconds. This is the
time when the image scanner is actually attempting to contact base unit. Relink
Time-Out controls the amount of time, in seconds, that elapses between the end
of one connection attempt and the start of the next.

Note: The length of time for an attempt depends on the number of image

scanners connected to a base unit. An extra 7 seconds may be required
when a connection is successful.

Scan the Relink Time-Out barcode, then scan the number of seconds for the
setting (from 1-100) from the inside back cover. Scan Save to save the setting.
Default = 3 seconds.

Bluetooth/ISM Network Activity Examples

Default values:

When the image scanner goes out of range, the image scanner repeatedly
attempts to connect to base unit. Each attempt consists of approximately 5
seconds of active time followed by 3 seconds of idle time. After one hour, the
image scanner powers off and batch mode data is lost.

Maximum Link Attempts set to 15
Other values at default setting:

When the image scanner goes out of range, 15 attempts are made to link to
the base unit. Each attempt consists of approximately 5 seconds of active time
followed by 3 seconds of idle time. After 15 cycles (8*15 =120), or about 2
minutes, the image scanner stops trying to connect to the base unit, but retains
any barcodes that may have been saved in batch mode. After one hour, the
image scanner powers off and batch mode data is lost.

Auto Reconnect Mode set to 0
Maximum Link Attempts set to 15
Other values at default setting:

When the image scanner goes out of range, no action is taken to re-link. When
the trigger is pulled, 15 attempts are made to link to the base unit. Each
attempt consists of approximately 5 seconds of active time followed by 3
seconds of idle time. After 15 cycles (8*15 =120), or about 2 minutes, the
image scanner stops trying to connect to the base unit, but retains any
barcodes that may have been saved in batch mode. After one hour, the image
scanner powers off and batch mode data is lost. Refer to (see

Auto Reconnect

Mode

on page B-1), to review other events that can start the re-link process.

Relink Time-Out