background image

2 - 16

Wand Emulation Data Block Size

This transmits the data in smaller blocks to prevent buffer overflow.

Default =

40.

Wand Emulation Delay Between Blocks

This sets the delay time between data blocks.

Default = 50ms.

Wand Emulation Overall Checksum

When this option is turned on, a computed check character is added at the end
of the entire message. The check character is the character which when Exclu-
sive-OR’d with every preceding character of the message yields a result of 0x00
(00H).

Default = Off.

20

80

* 40

60

5ms

500ms

* 50ms

150ms

* Wand Emulation Overall

Checksum Off

Wand Emulation Overall

Checksum On