SECTION 3. OPERATION

3-1. INTRODUCTION

This section provides operating procedures for the Blast Chiller.
Sections 1, 2, and 3 should be read, and all instructions should be
followed before operating the cabinet.

This section contains an explanation of all controls and compo-
nents and information on operating procedures and daily
maintenance.

If the blast chillers (that have compressors shipped with them)
have been laid on its side, the unit must be sitting upright for at
least an hour before applying power to the unit. Check all
components for signs of being loose or damaged, and make
sure the system has refrigerant. Failure to follow these
instructions may cause damage to the components. Failure to
follow these instructions could cause damage to the compres
sor.

3-2. OPERATING CONTROLS

Pages 3-1 to 3-4 identifies and describes the function of all the
operating controls.

Fig.

Item

Description

Function

No.

No.

3-1

1

On/Off Button

The On/Off button, when pressed, is a button on the
control panel that starts a chilling cycle. It also must be
pressed before any changes to the controls can be made,
and to start and stop the De-ice cycle.

3-1

2

Digital Display

The Digital Display shows the temperatures, the time
(in a timing cycle), and the information in the technical
mode.

3-1

3

Up and Down

The Up and Down Arrows are used when changing

Arrows

times or settings.

3-1

4

Alarm Button

The Alarm button is used to stop the optional alarm buzzer
and to enter the technical mode.

3-1

5

Temp Button

The Temp button is used to select either the chilling

mode.

3-1

6

De-ice Button

The De-ice button is used to remove ice that may have
formed on the evaporator during a chilling cycle.

3-1