3-7. PROGRAMMING

11.

The duration of time the temperatures, (in 9 and 10

(Continued)

above), must remain at before the alarms will sound.
Press the Alarm button 11 times and the digital display will

10

show the time at which the high and low temperatures (no.
9 and 10 above) must remain at, before the alarm will
sound.

The factory setting is 20 minutes, but can be changed to a
maximum setting of 60 minutes, or a minimum of 10 minutes
by pressing the Up and Down buttons.

This means, that the temperature must remain at a too high,
or too low temperature for 20 minutes before an alarm will
sound.

11

12.

International Only. A Frigiprobe sensor temperature
which can turn off the compressor, in a chilling cycle,
to prevent freezing of the product.
Press the Alarm
button 12 times and the digital display will show the tem-
perature, at which a sensor in the Frigiprobe will turn off the
compressor during a Frigiprobe mode. This will prevent the
outer surfaces of the product from freezing, however the
cooling time will be greatly increased.

The factory setting is 39ºF (4ºC), but can be changed to a
maximum setting of 122ºF (50ºC), or a minimum of 32ºF
(0ºC) by pressing the Up and Down buttons.

NOTE

Do not change this setting lower than the setting used in param-
eter 22, (next page).

NOTE

This function will only activate when the factory setting is
changed to above 40ºF (4ºC). England must have a setting
of 3ºC (37ºF).

12

13.

Re-initialize the controls to factory settings. Press the
Alarm button 13 times and the digital display will show
“dEF”, at which time the Up button is pressed and the unit
will shut down. Re-initialization is now complete.

NOTE

After re-initialization, the controls will default back to factory
settings. The temperature will be in Celsius and the values in
steps 12, 16, and 18, of this section, will need to checked to be
accurate for the country in which the unit is installed.