3-7. PROGRAMMING

17.

Frigiprobe temperature for when the buzzer sounds at

(Continued)

the start of a cycle. Press the Alarm button 17 times, and
the temperature that the buzzer will sound when the product

23

has reached the “danger zone” temperature, and must be
cooled to a “safe” temperature within the recommended
time, will be shown in the display.

The factory setting is 140ºF (60ºC), but can be changed to a
maximum setting of 176ºF (80ºC), and a minimum setting of
122ºF (50ºC), by using the Up and Down buttons.

NOTE

The settings for the U.S.A. must be 140ºF (60ºC) and for
England, 158ºF (70ºC).

30

18.

Selecting Fahrenheit or Celsius. Press the Alarm button
18 times and ºF or ºC will show in the display. Use the Up
and Down buttons to toggle from ºF to ºC, or vice versa.