Henny Penny BCC/BCR-140 User Manual

Page 28

Advertising
background image

Henny Penny

Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350

4-2. TROUBLESHOOTING
(Continued)

Problem

Cause

Correction

Green compressor indicator

Voltage across terminals 10-11

light off and compressor

of control board:

is working.

- Control board relay bad

Replace control board.

No voltage across terminals 10-11
of control board:
- Faulty contactor.Replace contactor.

Green fan indicator light

Voltage across terminals 8-9 of

on and fan(s) not working.

control board.
- Fan or capacitor bad

Replace fan or its capacitor.

- Fan thermo-switch tripped.

Allow the fan motor to cool to
see if the fan comes back on.
If the fan does not come back
on, or it keeps tripping, re-
place the fan.

No voltage across terminals 8-9
of control board:
- Faulty control board relay.

Replace control board.

All indicator lights off and

Check electrical supply.

Plug unit into receptacle, or

On/Off switch will not

reset wall circuit breaker.

operate.

Fuse of control board blown.

Change the fuse.

No voltage from the control

Change the control board.

board transformer.

Connector between the control

Check the connection.

board and display board not
connected properly.

Bad wire in the connector between

Replace the connector.

the control board and display
board.

100

4-4

Advertising