Henny Penny BCC/BCR-140 User Manual

Page 8

Advertising
background image

Henny Penny

Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350

(Continued)

2-2

201

2-2. UNPACKING

4.

Open door and remove packing from the inside of the unit.

5.

Peel off any protective covering from the exterior of the
cabinet.

6.

Your Blast Chiller is now ready for operation.

If the blast chiller has been laid on its side, the unit must be
sitting upright for at least an hour before applying power to
the unit. Check all components for signs of being loose or
damaged, and make sure the system has refrigerant. Failure
to follow these instructions may causedamage to the
components. Failure to follow these instructions could cause
damage to the compressor.

NOTE

Be certain to save any literature that is packed inside the
cabinet, or separate boxes.

2-3. ELECTRICAL

BCC-140

• 200 V, 50-60 Hz, 3 phase
• 208-240 V, 60 Hz, 3 phase
• 230 V, 50 Hz., 1 phase

BCC-175

• 200 V, 50-60 Hz, 3 phase
• 208-240 V, 60 Hz, 3 phase
• 400 V, 50 Hz., 3N phase

BCR-140 and 175

• 208-240 V, 60 Hz, single phase
• 230 V, 50 Hz, single phase
• 200 V, 50-60 Hz., single phase

BFR and BCR-350

• 200 V, 50-60 Hz, 3 phase
• 208-240 V, 60 Hz, 3 phase
• 400 V, 50 Hz., 3N phase

The data plate, located inside of the unit, will specify the correct
electrical supply. The unit requires a grounded receptacle with a
separate electrical line protected by a fuse or circuit breaker of the
proper rating.

The cabinet must be adequately and safely grounded
according to local electrical codes to prevent the possibil-
ity of electrical shock.