Henny Penny BCC/BCR-140 User Manual

Page 9

Advertising
background image

Henny Penny

Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350

201

2-3

2-3. ELECTRICAL

Refer to the table below for electrical ratings for both models.

(Continued)

Model No.

Volts

Watts

Amps

Freq. Phase

BCC-140

200

4700

18

50/60

3

208-240

4700

18

60

3

230

4700

20

50

1

BCC-175

200

5800

20

50/60

3

208-240

5800

20

60

3

400

5800

9

50

3N

BCR-140

208-240

2400

12

60

1

230

2400

10

50

1

200

2400

12

50-60

1

BCR-175

200

2400

12

50/60

1

208-240

2400

12

60

1

230

2400

12

50

1

BFR &

200

4100

15

50/60

3

BCR-350

208-240

4100

15

60

3

400

4100

10

50

3N

2-4. LOCATION

The Blast Chillers should be placed in an area where the doors can
be opened, for loading and unloading, without interruption. For
proper operation, the cabinet must be level.

For maximum efficiency, if the air temperature of the premises
is more than 100° F (38° C), the room should have adequate
ventilation, taking into account for the heat emitted by the unit.

Clearances should be as follows:

BCC/BCR-140 Top ........... 16 in. (400 mm) for air circulation

Left Side ... 4 in. (100 mm) for air circulation
Right Side . 8 in. (200 mm) for air circulation
Back ......... 4 in (100 mm) for air circulation
Front ........ 26 3/8 in (668 mm) for door swing

BCC/BCR-175 Top ........... 16 in. (400 mm) for air circulation

Sides ........ 3 in. (70 mm) for air circulation
Front ........ 33 3/8 in. (847 mm) for door swing

BFR &

Top ........... 16 in. (400 mm) for air circulation

BCR-350

Sides ........ 3 in. (70 mm) for air circulation

Pass Thru

- Front and Back ... 38 1/8 in (970 mm) for door swing

Solid Back

-Front ................... 38 1/8 in. (970 mm) for door swing

Back ................... 4 in. (100 mm) for air circulation