Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350

3-7. PROGRAMMING

14.

Blast chilling, low side air temperature limit, when using
the Frigiprobe, in step 12 of this section.
Press the Alarm
button 14 times and the low side air temperature, at which

20

the compressor cycles on and off, will show in the display.
This temperature is used in preventing the product from
freezing, while in the chilling mode, which is described in
step 12.

The factory setting is -4ºF (-20ºC), but can be changed to a
maximum setting of 32ºF (0ºC), and a minimum setting of
-31ºF (-35ºC), by using the Up and Down buttons.

21

15.

Blast chilling, high side air temperature limit, when using
the Frigiprobe, in step 12 of this section.
Press the Alarm
button 15 times and the high side air temperature, at which
the compressor cycles on and off, will show in the display.
This temperature is used in preventing the product from
freezing, while in the chilling mode, which is described in
step 12.

The factory setting is 32ºF (0ºC), but can be changed to a
maximum setting of 50ºF (10ºC), and a minimum setting of
23ºF (-5ºC), by using the Up and Down buttons.

22

16.

Frigiprobe, end of cycle temperature setting. Press the
Alarm button 16 times, and the temperature at which ends
the food probe cycle and starts the hold cycle, will show in
the display.

The factory setting is 39ºF (4ºC), but can be changed to a
maximum setting of 50ºF (10ºC), and a minimum setting of
32ºF (0ºC), by using the Up and Down buttons.

NOTE

The maximum settings for U.S.A. is 39ºF (4ºC), and for
England is 37ºF (3ºC).