INTRODUCTION

This section provides the installation instructions for the Henny Penny Electric Combi-Steamers.

NOTE: The installation of this unit must conform to all local, state, and federal codes. In the absence of codes use
ANSI/NFPA No. 70-latest edition.

NOTE: Canadian installations must conform with the Canadian electrical code, C22.1, Part 1 and/or local codes.

NOTE: The installation of this equipment should be performed by a qualified technician.

LOCATION

The proper location of the unit is very important for operation and convenience. Choose a location which will provide easy
loading and unloading without interfering with the final assembly of food orders.

NOTE: Adequate clearance must be provided for servicing and for operation.

Table Units:

Minimum clearances have to be maintained from the adjacent walls.

Left Side

Right Side

Back Side

CSB,CSM,CSL-6, 10, 1020

6” (150mm)

2” (50mm)

2” (50mm)

NOTE: 14” (350mm) is recommended at the left side of the unit for service purposes.

Place the combi-steamer on an original Henny Penny stand or on a level and sturdy surface. Recommended stand height
is 28.5” (725mm).

Minor unevenness of the surface/floor can be compensated by adjusting the legs of the stand or the appliance.

The weight of the units are as follows:

CSB, CSM, CSL-6

297 lbs.

(134.5 kg)

CSB, CSM, CSL-10

349 lbs.

(158.0 kg)

CSB, CSM, CSL-1020

507lbs.

(230.0 kg)

Installation planning should encourage sufficient space to keep the transport trolley/mobile rack at the left-hand side
of the unit.

NOTE: Ventilation must conform to local, state and national codes. Consult your local fire department or building authorities.

X

Do Not puncture the cabinet with any objects such as drills or screws as electrical shock, or component
damage could result.

X

When moving the unit with a pallet jack ensure it is located under the 1-5/8” x 1-5/8” structure frame before
lifting the unit.