EH1721 SERIES ELECTRIC FRYERS

CHAPTER 4: BUILT-IN FILTRATION

4-10

4.3.2 Filter Operation (cont.)

11. Larger systems may come equipped

with an optional hose and wand
system. To operate the system:

• With the oil drained to the

filter pan, connect the hose to
one of the connections on the
front of the fryer.

• Place the wand securely into

the frypot and turn on the
pump with the cabinet-
mounted wand switch.








12. Three-battery and larger systems may come

equipped with an optional drain flush. To use
the system:
• After filtering frypot #3 (farthest from the

filter) for 5 minutes, close the oil return
valve to stop the filtering process. Do not
refill the frypot.

• Close the drain valve (red handle) on the

frypot being filtered. Ensure all other
valves (red and yellow handles) are
closed.

• Pull the blue handle to open the flush

valve. After the drain line is clear of
sediment (approximately 2 minutes), push
the blue handle to close flush valve.

• Open the oil-return valve (yellow handle)

to refill the frypot.






With the filter pan full of
oil, connect the hose and
wand to the fryer
connection (left). Direct
the wand into the frypot
and activate the pump
with the cabinet-
mounted switch (below).

Drain-flush handle (blue) location.