Frymaster FPH1721 User Manual

Page 34

Advertising
background image

EH1721 SERIES ELECTRIC FRYERS

CHAPTER 5: OPERATOR TROUBLESHOOTING

5-4

5.2.2 Error Messages and Display Problems (cont.)

Problem

Probable Causes

Corrective Action

CM4-S and KFC-1

display shows

LOW.

Fryer temperature is below 255°F
(124°C).

This display is normal when the fryer
is first turned on. If the display never
goes out, the fryer is not heating and
may be malfunctioning. Shut the fryer
off and call FASC.

CM4-S and KFC-1

display shows

Ignition

Failure.

Fryer’s ignition module has failed. Fryer
will not ignite or heat.

Shut the fryer off and call FASC.

CM III.5

or

Digital Controller

display shows

.

CM4-S and KFC-1

display shows

PROBE FAILURE.

Problem with the temperature measuring
circuitry including the probe.

Shut the fryer off and call FASC.

CM III.5 frypot

temperature is

displayed constantly.

Computer is programmed for constant
temperature display.

Refer to the separate Frymaster Fryer
Controllers User's Manual
for
instructions on toggling between these
display options.

5.2.3 Basket Lift Problems

Problem

Probable Causes

Corrective Action

Basket lift movement

is noisy, jerky, or

erratic.

Lack of lubrication on basket lift rods.

Apply a light coating of Lubriplate or
similar lightweight white grease to the
rod and bushings.

5.2.4 Built-in Filtration Problems

Problem

Probable Causes

Corrective Action

A. Power cord is not plugged in or circuit

breaker is tripped.

A. Verify that the power cord is fully

plugged in, circuit breaker is not
tripped.

Filter pump won't

start.

B. Pump motor has overheated causing

the thermal overload switch to trip.

B. Allow the motor to cool at least 45

minutes then press the Pump Reset
Switch.

Filter pump won’t

start. (cont)

C. Blockage in filter pump.

Test: Close the drain valve and pull
the filter pan out from the fryer.
Activate the pump. If the pump motor
hums for a short time then stops, the
probable cause is blockage of the
pump itself.

C. Pump blockages are usually caused

by sediment buildup in the pump
due to improperly sized or installed
filter paper and failure to use the
crumb screen. Call FASC.


Advertising