3. Wrap the motor with plastic wrap to prevent water from entering it. Spray degreaser or detergent

on the blower wheel and the blower housing. Allow it to soak for five minutes. Rinse the wheel
and housing with hot tap water, then dry with a clean cloth.

Wrap the motor and

wires with plastic wrap

or a plastic bag.

BLOWER HOUSING

BLOWER WHEEL

4. Remove the plastic wrap from the blower motor assembly. Reassemble the blower motor

assembly and blower housing. Reinstall the blower assembly in the fryer.

5. Reinstall the blower shield or shield assembly.

6. Light the fryer in accordance with the procedure described in Chapter 3, Section 3.1.

7. After the burners have been lit for at least 90 seconds, observe the flames through the burner

viewing ports located on each side of the combustion air blower.

The air/gas mixture is properly adjusted when the burner manifold pressure is in accordance with the
applicable table on page 3-7 and the burners display a bright orange-red glow. If a blue flame is ob-
served, or if there are dark spots on a burner face, the air/gas mixture requires adjustment.