3.8.2 Troubleshooting the Gas Valve

CONTROLLER

IS CALLING

FOR HEAT.

For non-CE units, verify

gas valve is in ON

position.

Is 24VAC

present across gas

valve main coil?

Is incoming

gas pressure in

accordance with tables in

Section 2.3

of this manual?

Yes

Is outgoing

gas pressure in

accordance with tables on

page 3-7

of this manual?

Yes

Gas valve is OK>

Yes

Probable cause is misadjusted

or failed gas valve. Adjust gas valve in

accordance with Section 3.4 of this

manual. If valve cannot be

adjusted, replace valve.

No

Problem is with

gas supply to fryer.

No

Problem is with 24VAC Circuit.

Refer to "Troubleshooting the
24VAC Circuit" on page 3-30.