3.8.1 Troubleshooting the 24VAC Circuit

UNIT IS CONNECTED TO

POWER SUPPLY, DRAIN

VALVE IS FULLY

CLOSED, CONTROLLER

IS ON AND CALLING

FOR HEAT (heat mode

indicator is illuminated).

NOTE: All voltage measurements must

be made within 4 seconds of unit calling

for heat. If unit does not fire within 4

seconds, ignition modules will lock out

and the computer must be turned off then

back on to reset.

Is 24VAC

present on interface

board J3 pin 9 (LED 5 (GV)) and,

on dual vat units, J1 pin 9

(LED 1 (GV))?

Is 24VAC

present across gas valve main

coil (PV terminal) (on both valves

if dual vat)?

Yes

24V circuit is OK.

Problem may be

with gas valve.

Yes

Probable causes are an open high-limit

or a failed wire between the interface

board and the gas valve. On units with

built-in filtration, cause may also be a

failed drain safety switch.

No

Check continuity of high-limit and

continuity of drain safety switch.

If both are zero,

problem is in wiring.

Is LED 3 (24V)

lit continuously?

No

Probable causes are a failed

24V transformer, failed

wiring between transformer and interface

board or fuse on 106-0386 interface

board.

No

Is 24VAC

present on the right PWR

terminal (LED 4) (and left PWR

terminal (LED 2), if

dual vat)?

Yes

Probable cause

is a failed interface

board.

No

Is 24VAC

present on V1S (or

V1D and V2D, if

dual vat)?

Yes

Probable cause is a

failed interface board.

Yes

If ignition module fuse

is good, probable causes are a

failed ignition module or a failed

interface board. Replace suspect

ignition module with one known

to be good to isolate cause.

No