background image

3-6

4.

Remove the wire and blow through the tube to ensure it is clear.

5.

Reinstall the tube and bend it so that the opening is pointing downward.

3.4

Checking the Burner Manifold Gas Pressure

DANGER

Frymaster recommends that ONLY qualified service personnel perform this task.

1. On non-CE fryers, ensure that the gas valve knob is in the OFF position.

Honeywell

ON

OFF

2. Remove the pressure tap plug from the gas valve assembly.

Typical Non-CE

Valve Assembly

Typical CE Valve

Assembly

Pressure Tap Plug

2. Insert the fitting for a gas pressure-measuring device into the pressure tap hole.

3. On non-CE fryers only, place the gas valve in the ON position.

4. Place the fryer power switch in the ON position. When the burner has lit and burned steadily for

at least one minute, compare the gas pressure reading to the pressure for the corresponding gas in
the appropriate table found on the following page.