Frymaster BIH52 User Manual

Page 14

Advertising
background image

2-5

2.4

Connection to Gas Line

The H52 Series has received the CE mark for the countries and gas categories indicated in the
accompanying table. NOTE: The nominal heat input (Qn) is 21kW except for AT, DE, LU, and for
category 3B/P under 50 mbar, which is 23kW.

COUNTRIES

CATEGORIES

GAS

PRESSURE (mbar)

G20

20

G30, G31

50

I

2E(R)B

G20, G25

20, 25

I

3+

G30, G31

28-30, 37

G20

20

G30, G31

30

G20, G25

20, 25

G30, G31

28-30, 37

G20, G25

20, 25

G31

50

G20

20

G30, G31

30

G20, G25

20

G30, G31

50

I

3P

G31

50

G20

20

G30, G31

28-30, 37

G20

20

G30, G31

28-30, 37

G20

20

G30, G31

28-30, 37

G20

20

G30, G31

50

G25

25

G31

50

G25

25

G30, G31

30

NORWAY (NO)

I

3B/P

G30, G31

30

G20

20

G30, G31

28-30, 37

G20

20

G30, G31

28-30, 37

G20

20

G31

37, 50

G20

20

G30, G31

30

G20

20

G30, G31

28-30, 37

II

2ELL3B/P

II

2H3B/P

II

2Esi3+

II

2Esi3P

II

2H3B/P

II

2E3B/P

II

2H3+

II

2H3+

II

2H3+

II

2H3+

II

2H3+

II

2L3B/P

II

2L3P

UNITED KINGDOM (GB)

II

2H3+

II

2H3B/P

II

2H3P

NETHERLANDS (NL)

PORTUGAL (PT)

SPAIN (ES)

SWEDEN (SE)

GREECE (GR)

ITALY (IT)

IRELAND (IE)

LUXEMBOURG (LU)

DENMARK (DK)

FRANCE (FR)

FINLAND (FI)

GERMANY (DE)

CE Approved Gas Categories by Country*

AUSTRIA (AT)

II

2H3B/P

BELGIUM (BE)

* H152-2 units are not approved for G30 (Butane) gas.

The size of the gas line used for installation is very important. If the line is too small, the gas pres-
sure at the burner manifold will be low. This may cause slow recovery and delayed ignition. Fry-
master recommends the incoming gas supply line be a minimum of 1½” (38 mm) in diameter. Refer
to the chart on the following page for the minimum sizes of connection piping.

Advertising
This manual is related to the following products: