3.8.3 Troubleshooting the Temperature Probe

While it is still in the

frypot, inspect probe

body for damage.

Remove and replace if

bent, dented or cracked.

Inspect leads for fraying,

burning, breaks, and/or

kinks. If found, replace

probe.

Determine temperature of

cooking oil/shortening using

a thermometer or pyrometer

placed at tip of probe.

Is resistance through

J3 pins 2 and 6 (J1 pins 2 and 6 for

left side of dual vat) approximately equal to

that given in Probe Resistance Chart for

the corresponding temperature?

Measure resistance through

each of the previously tested

pins to ground.

Yes

Is resistance

5 megaohms or greater in

each pin?

Probe has failed.

No

Problem is not

with probe.

Yes

No

Note: Disconnect computer before measuring probe resistance.