5-7

WARNING

Use caution and wear appropriate safety equipment when resetting the filter pump
reset switch. Resetting the switch must be accomplished with care to avoid the
possibility of a serious burn caused by careless maneuvering around a drain tube
and around a frypot.


10. Ensure the drain valve is fully closed. (If the drain valve is not fully closed, the fryer will not

operate.) Turn the fryer ON and allow the cooking oil to reach setpoint.

DANGER

The crumb tray in fryers equipped with a filter system must be emptied into a
fireproof container at the end of frying operations each day. Some food particles can
spontaneously combust if left soaking in certain shortening material.

WARNING

Do not bang fry baskets or other utensils on the fryer’s joiner strip. The strip is
present to seal the joint between the fry vessels. Banging fry baskets on the strip to
dislodge shortening will distort the strip, adversely affecting its fit. It is designed for
a tight fit and should only be removed for cleaning.


5.4

Disassembly and Reassembly of the Magnasol Filter


Dissassembly

1. Grasp the frame with your thumbs on the handles at the corner of the assembly and pull outward

in opposite directions to separate the frame at the corner. Continue to open the frame (it will
pivot at the opposite corner) until the outer screens and grid can be removed from the frame.

Step 1 - Grasp frame with
thumbs on these handles and
pull frame appart at corner.

Step 2 - Separate

the outer screens

and grid.

2. Separate the outer screens and grid.