Frymaster 8196339 User Manual

Page 65

Advertising
background image

7-5

PROBLEM

PROBABLE CAUSES

CORRECTIVE ACTION

Filter pump runs,

but oil return is very

slow and bubbling

oil occurs.

A. Paper/screen clogged.
B. Improperly installed filter pan

components.

C. Attempting to filter with oil that

is not hot enough.

A. Paper/screen needs changed or

cleaned.


B. If using filter paper

configuration, verify that filter
screen is in bottom of pan with
paper on top of screen.

Verify that O-rings are present
and in good condition on filter
pan connection fitting.

C. In order to properly filter, the oil

should be at or near 350ºF
(177ºC).

Filter pump runs

but oil does not

return to frypot and

there is no bubbling

oil.

Blockage in filter pan suction tube.
Test: Close the drain valve and pull
the filter pan out from the fryer.
Activate the pump. If bubbling oil
occurs, there is a blockage in the
filter pan suction tube.

The blockage may be caused by
sediment buildup. Use a thin,
flexible wire to remove the
blockage. If the blockage cannot be
removed, call FASC.


7.2.4 Auto Top-Off Problems

Problem

Probable Causes

Corrective Action

Frypots won’t top

off.


A. Fryer temperature too low.
B. Temperature of oil too cold.
C. Supply line out of JIB.
D. CM7 not readdressed after ATO

switch was switched on.


A. Fryer temperature must be at

least 300°F (149°C).

B. Ensure that oil is above 70°F

(21°C).

C. Ensure supply line is in JIB.
D. Switch all CM7 computers off

and then on again to readdress
system.


If problem persists call your FASC.

7.2.5 Basket Lift Problems

PROBLEM

PROBABLE CAUSES

CORRECTIVE ACTION

Basket lift

movement is jerky

and/or noisy.

Basket lift rods need lubrication.

Apply a light coating of
Lubriplate

or similar lightweight

white grease to the rod and
bushings.

Advertising