As HEATING MODE indicator lights,
does the right HT LED light (both HT

LEDs for split-vat units)?

Probable causes are:

1. Broken or improper wire

connection

2. Defective interface board

Probable causes are:

1. Defective interface board
2. Broken or defective wiring

connection

3. Defective heating contactor

Is 24 VAC present on the

Heating Contactor and does the

Heating Contactor close?

NO

YES

NO

Is the right HI LED lit (for split vat

units, both HI LEDs lit)?

Is 24VAC present on the Latching

Contactor AND does the contactor

close?

Probable causes are:

1. Open high-limit
2. Open/defective drain-valve microswitch
3. Broken or improper wire connection
4. Defective latching relay

Probable causes are:

1. Defective latching relay
2. Defective latching contactor
3. Defective interface board
4. Broken or improper wire connection

NO

NO

YES

YES

CONTINUED FROM

PRECEEDING PAGE

Continued on

next page

YES