Common electric mcdonald's h14 series— dual-vat, Computer/ controller, J1 j2 – Frymaster H14 Series User Manual

Page 68

Advertising
background image

7-18

3 PHASE POWER
TERMINALS

GND

LATCHING
CONTACTOR

3

1

2

3

2

1

1C

2C

LATCHING
CONTACTOR

3

1

2

3

2

1

3C

4C

J3

J3

2

6

15

5

10

13

14

4

11

TROUBLE

HEAT

POWER

ON

POWER

ON

HEAT

TROUBLE

12V

3

1

1

3

3

24V

2

24V

24V
FUSE

DRAIN
SAFETY
SWITCH

4

7

4

7

HIGH
LIMIT

K4
LATCH
RELAY

K3
HEAT
RELAY

HI

HT

K1
LATCH
RELAY

AL

K2
HEAT
RELAY

TEMP
PROBE

AL

HT

2

6

14

14

15

12

12

COMP

14

13

10

J1

3

2

J1

J2

J2-10

11

12

1

J1-5

J1-6

C6-14

11

5

5

J2-5

J2-9

C6-8

J2-8

L3

L2

L1

C6

12

13

6

7

C6

HI

DRAIN
SAFETY
SWITCH

HIGH
LIMIT

TEMP
PROBE

1/50

1/50

1/50

1/50

A

A

AA

47K

47K

47K

47K

1K

1K

1K

1K

1/50

1/50

1/50

1/50

A

A

AA

47K

47K

47K

47K

1K

1K

1K

1K

C1-8

10K

10K

10K

10K

J1-9

J4-1

J4-3

C1-1
C1-3

CONTROL CIRCUIT

COMMON ELECTRIC McDONALD'S H14 SERIES— DUAL-VAT

T

M

T

M

BURN-OFF
RELAY

SD

COMPUTER/
CONTROLLER

Advertising