7-11

7-8: REPLACE CONTACTOR

1. Perform Procedure 7-4, Replace Temperature Probe, Steps 1-3.

2. Remove the screws securing the bottom and center rear access covers. Set the screws and covers

aside.

3. If present, remove the screws securing the

wiring covers to the front of the contactor box
(optional on old-style contactor boxes). Set
the screws and covers aside.

4. Disconnect the wire harnesses from the front

and rear of the contactor box.

5. Remove the screws securing the contactor

box to the bottom frame of the fryer.

6. Pull the contactor box through the access

opening in the rear of the fryer.

7. Remove the screws securing the contactor

box cover. Set the screws and covers aside.

8. Remove all wiring connected to the contactor

terminals inside the contactor box. Mark
each wire for re-assembly.

Screws securing wire cover to contactor box (optional

on old-style contactor boxes)

Location of screws securing contactor box to bottom frame

Mark each wire for re-assembly, then remove all
wiring connected to the contactor(s) to be replaced.