Frymaster H14 Series User Manual

Page 46

Advertising
background image

6-6

6.2.2 Troubleshooting Fryers Equipped with Analog Controllers

Fryer Off

Press the ON/

OFF switch (OFF

displayed in

window).

CONTROLLER

PANEL OPEN

INTERFACE

BOARD VISIBLE

Is the CMP LED in the top

center of the interface board

illuminated?

Is the 24V LED on the

interface board

illuminated?

Is the AL LED illuminated?

Condition normal.

Probable causes are:

1. Defective 24-volt transformer
2. Defective interface board
3. Broken or improper wire connection

Probable causes are:

1. Defective interface board

NO

NO

NO

YES

YES

YES

Probable causes are:

1. No power applied to the fryer power

cord

2. Defective 12-volt transformer
3. Defective interface board
4. Broken or improper wire connection

Advertising