Frymaster Gas Rethermalizers FBKR18 Series User Manual

Page 14

Advertising
background image

2-6

2. Open the gas supply to the fryer and check all piping, fittings, and gas connections for leaks. A

soap and water solution should be used for this purpose.


3. Close the drain valve and fill the cookpot with water and boil-out solution to the overflow. Light

the burners and perform the boil-out procedures that are described in the “Start-Up Procedure”
and “Boiling Out the Cookpot” sections in Chapter 3 of this manual.

4. It is suggested that the burner manifold pressure be checked at this time by the local gas com-

pany or an authorized service agent. Refer to “Check Burner Manifold Pressure” in Chapter 4 of
this manual for the proper procedure.


2.5

Converting to Another Gas Type


This equipment is configured at the factory for either natural gas or LP (Propane) gas.

If you desire to switch from one type of gas to the other, a gas conversion kit must be installed by a
Factory Authorized Service Center technician.

DANGER

This appliance was configured at the factory for a specific type of gas. Converting
from one type of gas to another requires the installation of specific gas-conversion
components.

Switching to a different type of gas without installing the proper conversion kit may
result in fire or explosion! NEVER ATTACH THIS APPLIANCE TO A GAS SUPPLY
FOR WHICH IT IS NOT CONFIGURED.

Conversion of this appliance from one type of gas to another should only be
performed by qualified, licensed, and authorized installation or service personnel, as
defined in Section 1.6 of this manual.

Advertising