Frymaster Gas Rethermalizers FBKR18 Series User Manual

Page 47

Advertising
background image

6-14

6.8.2 Troubleshooting the 24 VAC Circuit

WATER LEVEL IN

COOKPOT IS ABOVE

LOWER WATER

LEVEL SENSOR AND

COMPUTER IS

ACTIVATED.

Is 24VAC

present on J2

Pin 7?

Probable cause is a

failed transformer.

Is LATCH

LED illuminated?

Probable cause is failed

computer or failed 15-pin

wiring harness.

Is combustion

air blower runing?

Is 12VDC

present on J4

pin 5?

Probable cause is a

failed computer.

Is cookpot filling?

Is HEAT LED

illuminated?

Is 24VAC

present on J2

Pin 4?

Probable cause is a

failed interface board.

Probable cause

is a failed interface board

or failed temperature

probe.

Is 24VAC

present on gas

valve?

24VAC circuit

is OK.

Is WATER LED

illuminated?

Probable causes are dirty
low water sensor or failed

interface board, in that

order.

Probable causes are blown

ignition module fuse, failed

ignition module, or failed

centrifugal switch in blower, in

that order.

Is 24VAC

present on J2

pin 2?

Probable causes are

grounded high water level

sensor or failed interface

board.

Probable causes are

failed solenoid valve or

broken or loose wire.

Yes

Yes

Yes

No

Yes

Yes

No

No

Yes

No

No

No

No

Yes

No

Yes

No

Yes

Yes

No

Advertising
This manual is related to the following products: