Frymaster Gas Rethermalizers FBKR18 Series User Manual

Page 30

Advertising
background image

5-3

WATER NOT

HEATING. AUTOFILL

WORKED PROPERLY.

Press the

Temperature

Check button twice

to display setpoint.

Is the

displayed setpoint

correct?

Enter correct setpoint in

accordance with

instructions in Chapter 3.

Did burners

light?

Did water

reach setpoint

temperature?

Problem

resolved.

Refer to troubleshooting

guide "BURNERS DO NOT

LIGHT".

Insert a good grade thermometer

into cookpot with tip near the

temperature probe and wait two

minutes. Press the Temperature

Check button once to display the

cookpot temperature.

Is the temperature

displayed reasonably close to

the thermometer

reading?

Temperature control

features are working properly.

If water still fails to reach

setpoint, call FASC.

There is a problem in

the temperature probe

circuit. Call FASC.

Yes

No

Yes

No

No

Yes

No

Yes

Advertising