Frymaster Gas Rethermalizers FBKR18 Series User Manual

Page 27

Advertising
background image

4-4

3. Place the gas valve in the ON position. Place the computer power switch in the ON position.

When the burner lights and continues to burn, compare the indicated pressure to the table
below.

Burner Manifold Gas

Pressures

Gas

Pressure

Natural

3.5" W.C.

0.8 kPa

LP

8.25" W.C.

2.5 kPa

4. If necessary, adjust the burner gas pressure by removing the cap from the gas valve regulator

and turning the regulator screw to obtain the correct pressure. When the correct pressure is
obtained, reinstall the cap.

5. Place the rethermalizer power switch and the gas valve in the OFF position. Remove the fitting

from the pressure tap hole and reinstall the pressure tap plug.