Frymaster Gas Rethermalizers FBKR18 Series User Manual

Page 19

Advertising
background image

3-5

NOTE 1: Programming mode is not available while the computer is rethermalizing; the display
will flash BUSY.

NOTE 2: To toggle between Fahrenheit and Celsius temperature display, press the Program
Mode

switch, then enter the code 1 6 5 8 by pressing the corresponding product buttons.

Next, press the Temperature Check/Program Lock switch to lock in the new display option.

3. Enter the number 1 6 5 0 by pressing the corresponding product buttons. Unless this code is

entered, programming will not be accepted. This is to prevent unauthorized changes to your
current instructions.

4. SP-r (Setpoint) appears in the left LED display. Any previously programmed temperature

setpoint appears in the right display. To change the setpoint, enter the desired setpoint
temperature using the corresponding product buttons. The setpoint can be programmed for any
value up to 212°F (100°C). Press the Program Mode switch to lock in the new setpoint (or
the old setpoint, if it was not changed).


5. SELP (Select Product) appears in the left display. Press the product button to be programmed

(or press to return to the normal operating mode).


6. COOC (Rethermalizing Time) appears in the left display. Any previously programmed

rethermalizing time will appear in the right display. Press to accept the current
rethermalizing time or enter a new time using the product buttons. The rethermalizing time can
be programmed up to 59:59. Press to lock in the new time.

NOTE: The computer can be programmed for either “standard” or “slow” clock. The standard
clock displays minutes and seconds, the slow clock displays hours and minutes. To toggle back
and forth between times press the Program Mode switch, then enter the code 1 6 5 3 using
the product buttons. Press the Temperature Check/Program Lock switch to lock in the clock
speed. To determine whether the clock speed is set to standard or slow, initiate a rethermalizing
cycle by pressing a product button. If the computer is set to the standard clock, the time in the
LED display will immediately begin to count down. If it does not, the computer is set to the
slow clock.


7. SH1 (Stir Time 1) appears in the left display. Enter the number of seconds to heat before the

stir alarm sounds using the product buttons; for no stir alarm, enter “0”. The number entered
will appear in the right display. For example, entering “30” means the product needs to be
stirred after it has been rethermalizing for thirty seconds.

The stir time can be programmed up to 59:59, but must not exceed the product rethermalizing
time
. Press to lock in the programmed time.

SH2 appears. Program the time of the second stir alarm as above, being sure that the time

entered is greater than that for stir alarm 1 or else is “0”.

SH3 appears. Program the time of the third stir alarm in the same manner as for Stir Times 1
and 2, being sure that the time entered is greater than that for stir alarm 2 or else is “0”.

CAUTION

Advertising